    HSE ALERT: UNAUTHORISED ACCESS TO SCAFFOLDS

    hselogo1Regulator sets out new guidance to protect children and the public

    HSE has issued Safety Alert CON1 2018 entitled Preventing unauthorised access onto scaffolding and other work platforms regarding the prevention of unauthorised access onto scaffolding or other work platforms.

    Falls from height from scaffolding or incomplete buildings following unauthorised access by the public frequently involve children and result in major and sometimes fatal injuries.

    Access points may be designed for access or be opportunistic.  HSE stress that all such routes may need to be secured by a combination of perimeter fencing, local fencing and ladder removal out of working hours, or securing ladders using a suitable ladder guard to make them unclimbable (see image below).

    HSE stress that the Safety Alert is

    “not aimed at preventing all urban adventurers, determined trespassers, vandals or opportunistic thieves from finding a way onto a construction site.”

    It sets out the basic measures that must be taken, many of which will also provide a degree of deterrence against those more able and determined to enter the site/area.

    Actions required

    The Safety Alert sets out the actions required under the following headings:

    • Site Assessment
    • Site Perimeter Fencing
    • Local Fencing to Vulnerable areas on the Scaffold
    • Ladder Removal
    • Ladder Guards
    • Other Controls e.g. CCTV

    HSE conclude that the site risk assessment should be kept under review and reports of damage to site or local fencing or trespassing out of working hours should be investigated and security measures reviewed as a matter of urgency.

     

    A ladder guard that is not wide enough for the ladder it is fitted to.  Small feet can still climb the exposed rungs and the guard could slide even further to one side. Narrow ladder guards are only suitable for narrow ladders. No more than 50mm of exposed rung should be visible when the guard is tight to one side of the ladder.

    Latest Construction Health and Safety News

    ASBESTOS REMOVED WITHOUT SURVEY OR CONTROLS

    Client fined over failure to commission refurb and demo survey

    Read the rest of this article »

    Posted on 15th July 2019

    ‘VICTORIAN’ SAFETY AND FATIGUE BEHIND RAIL DEATH

    Investigation report links zero hours contracts to hazardous fatigue

    Read the rest of this article »

    Posted on 13th July 2019

    MPS EXAMINE CONSTRUCTION RESPIRATORY HEALTH

    Parliamentary group calls for evidence on the impact of worker silicosis

    Read the rest of this article »

    Posted on 12th July 2019

    UNSAFE LIFTING OPERATION TRAPPED WORKMAN

    Sling failure and inadequate lifting plan resulted in leg amputation

    Read the rest of this article »

    Posted on 12th July 2019

    HSE ENFORCEMENT DATABASE LATEST UPDATE

    hselogo1View current online register of HSE prosecutions and enforcement notices

    Read the rest of this article »

    Posted on 11th July 2019

    TIMBER FRAME FIRM FAILED ON FIRE AND FALLING

    House builder fined after routine HSE site inspection

    Read the rest of this article »

    Posted on 11th July 2019

    FIRM FAILED TO ACT ON SILICA DUST RISK

    Cutting of paving flags exposed workers to respirable crystalline silica

    Read the rest of this article »

    Posted on 11th July 2019

    POST GRENFELL BUILDING SAFETY SYSTEM REVIEW

    Structural safety body seek support for key reporting role

    Read the rest of this article »

    Posted on 11th July 2019

    OVERCOME BY CUTTING IN CONFINED SPACE

    Construction worker suffered carbon monoxide poisoning

    Read the rest of this article »

    Posted on 8th July 2019

    APPRENTICE OVERCOME BY CHEMICAL VAPOUR

    Stripping operations lacked ventilation controls, RPE and training

    Read the rest of this article »

    Posted on 8th July 2019

    DEBRIS FROM DEMOLITION SITE NOT RESTRAINED

    Loss assessor on adjacent property injured by stray waste

    Read the rest of this article »

    Posted on 8th July 2019

    WORKMAN FELL FROM UNGUARDED FLAT ROOF

    Basic work at height management systems and training absent

    Read the rest of this article »

    Posted on 8th July 2019

    CONSTRUCTION FATALITIES FALL TO RECORD LOW

    hselogo1HSE release final annual workplace fatality figures 2018/19

    Read the rest of this article »

    Posted on 3rd July 2019

    FEMALE WORKER SCALPED AND BADLY INJURED

    Wood product manufacturer fined £466,000 over rotating shaft danger

    Read the rest of this article »

    Posted on 2nd July 2019

    TOWER SCAFFOLD FALL CAUSED LONG-TERM DAMAGE

    Principal Contractor director and two firms sentenced after worker fall

    Read the rest of this article »

    Posted on 2nd July 2019

    MISSING PEDESTRIAN BARRIER TRIGGERED DEATH

    Workman walked from building into path of moving lorry

    Read the rest of this article »

    Posted on 26th June 2019

    WORKMAN SURVIVED 9M FLAT ROOF FALL

    Suitable and sufficient edge protection not provided

    Read the rest of this article »

    Posted on 26th June 2019

    PRISON SENTENCE FOR IGNORING HSE PROHIBITION

    Roofing contractor sentenced over unsafe working at height

    Read the rest of this article »

    Posted on 15th June 2019

    FIRM FAILED ON SILICA RISK MANAGEMENT

    Dust exhaust ventilation, RPE and health surveillance all absent

    Read the rest of this article »

    Posted on 14th June 2019

    WOMAN DIED TRAPPED IN POWERED ROLLER DOOR

    Firm did not check the operation of the safety sensors

    Read the rest of this article »

    Posted on 12th June 2019

    HSE TO HELP DITCH ‘UNNECESSARY PAPERWORK’

    Board considers forthcoming HSE guidance on navigating H&S rules

    Read the rest of this article »

    Posted on 12th June 2019

    SCAFFOLDER DIED IN FALL THROUGH FRAGILE ROOF

    Contractor given prison term and main contractor fined

    Read the rest of this article »

    Posted on 12th June 2019

    ENERGY BUSINESS FINED OVER LIFTING FATALITY

    Firm failed to train in lorry mounted crane remote control risk

    Read the rest of this article »

    Posted on 12th June 2019

    MAJOR FIRM FINED £800K OVER LIFTING ERRORS

    Workman injured by falling heavy expanded polystyrene block

    Read the rest of this article »

    Posted on 7th June 2019

    NEW APPROACH TO HIGHWAYS HEALTH AND SAFETY

    Highways England launches ‘Home Safe and Well’ strategy

    Read the rest of this article »

    Posted on 5th June 2019
    Ethentic Ethentic Higher Safety Higher Safety Chipmunk Data Chipmunk Data
  • Higher Safety Higher Safety Chipmunk Data Chipmunk Data Ethentic Ethentic