HSE SAFETY ALERT: SCAFFOLDING LOADING BAYS

Use of cable ties to secure loose mesh and unsafe means of operation

The Health and Safety Executive has published Safety Alert Bulletin No: FOD 2-2015 (Issue Date: 21 July 2015) after becoming aware that a number of manufacturers/suppliers are marketing an extendable scaffold loading bay gate which does not satisfy legal requirements or applicable standards when in some configurations.

When extended the loading bay gate, which forms part of the edge protection on a scaffold, is not robust enough to fulfil this function and is therefore not suitable and sufficient to comply with the Work at Height Regulations 2005. This safety notice applies to all similar types of loading bay gate as described in the Safety Alert.

Action required:
  • For gates of the type described in this safety alert stainless steel cable ties will be accepted as an interim measure for securing the mesh panel, and should be installed to the gate supplier’s instructions. Typically this will be one cable tie per 300mm. Unless the gate manufacturer/supplier allows a lighter duty cable tie, ties rated at minimum 75kg loop tensile strength should be used. Note that most cable ties are not designed to be suitable for reuse following loosening or removal. Alternatively, this aspect of the safety alert can be complied with by installing the extendible gate in the fully closed (narrowest) configuration thereby not requiring the use of cable ties.
  • Stainless steel cable ties should be included as part of the 7 day scaffold inspection.
  • Options to allow the gates in question to be opened without workers being able to slip or trip and fall through the gap underneath the open gate or the large gap while opening the gate include remote opening using rope over a scaffold rail or pulley fixed above and inboard of the closed gate. Or moving the gate pivot further inboard and extending the operating levers – this may remove the need to fully rotate the gate during opening. Both these methods allow operation from the rear of the loading bay platform – ie at least 2m back from the open edge
  • HSE has been informed that the supplier of one model of the gates in question is working on a design change to bring the gate to a standard that meets EN 12811-1 during operation and use. HSE expects manufacturers/suppliers of similar gates to do the same. These improvements will need to address the securing of the mesh infill panels; the risk of the gate opening due to a person or materials falling against it; and the level of fall protection provided when the gate is operated or open
  • Cable ties are not a permanent solution, However it is appreciated that many of these gates are manufactured and shipped from overseas and that changes will take time to implement. HSE will accept the correct use of stainless steel cable ties as an interim measure until the end of December 2016. After that date Enforcement Notices will be considered on a case by case basis for inadequate gates and/or gate designs. During the interim period gate installations that do not meet the minimum standard set out in this document will be subject to appropriate enforcement action.

Latest Construction Health and Safety News

LORRY SHEETING ARRANGEMENTS PROVED FATAL

Driver fell 4m to death during unsafe un-sheeting of lorry

Read the rest of this article »

Posted on 16th November 2017

HSE ENFORCEMENT WEEKLY UPDATE 15th NOV 2017

hselogo1Prosecutions and enforcement notices weekly update and analysis

Read the rest of this article »

Posted on 16th November 2017

NEW CPA GUIDANCE ON FORWARD TIPPING DUMPERS

Industry aims to help prevent overturns and collision with workers

Read the rest of this article »

Posted on 13th November 2017

DEMOLITION WORKER LOST BALANCE IN FATAL FALL

Lack of measures in place to prevent fall from mezzanine floor

Read the rest of this article »

Posted on 13th November 2017

GROUNDWORKER SET ON FIRE BY CABLE STRIKE

RAMS requirement for underground service checks not followed

Read the rest of this article »

Posted on 13th November 2017

HSE ENFORCEMENT WEEKLY UPDATE 8th NOV 2017

hselogo1Prosecutions and enforcement notices weekly update and analysis

Read the rest of this article »

Posted on 9th November 2017

RARE SUPPLIER PROSECUTION OVER FATAL CRUSHING

Vehicle manufacturer design and unsafe user practice caused death

Read the rest of this article »

Posted on 9th November 2017

ASBESTOS SURVEY FAILED TO COVER ALL WORK AREAS

Utilities firm fined after electricians exposed to drilled asbestos

Read the rest of this article »

Posted on 8th November 2017

METAL GRID FELL FROM FLT DURING PAINTING

Steel fabricator could have used sling to safely suspend grids

Read the rest of this article »

Posted on 7th November 2017

DRIVER ESCAPES WITH LIFE AFTER POWER STRIKE

Director given suspended sentence over lorry 132kV line contact

Read the rest of this article »

Posted on 7th November 2017

SCAFFOLDER FELL ON TEMPORARY ROOF WORKS

Injured workman lacked training and fall arrest equipment

Read the rest of this article »

Posted on 7th November 2017

FALLING CONTROL PANEL CRUSHED WORKMAN

Planning lacking on how to safely move heavy electrical equipment

Read the rest of this article »

Posted on 7th November 2017

POWER DOOR INSTALLER JAILED FOR THREE YEARS

Falling electrically powered gate claimed life of resident

Read the rest of this article »

Posted on 3rd November 2017

HSE ENFORCEMENT WEEKLY UPDATE 2nd NOV 2017

hselogo1Prosecutions and enforcement notices weekly update and analysis

Read the rest of this article »

Posted on 2nd November 2017

STEEL FIRM REMOVED BAND SAW SAFETY GUARD

Leg of worker crushed in the vice of an industrial band saw

Read the rest of this article »

Posted on 2nd November 2017

WORKMAN FELL AFTER RAIL REMOVED FOR ACCESS

Small builder failed to allow for missing guard-rail

Read the rest of this article »

Posted on 2nd November 2017

FINES RISE RAPIDLY ALONGSIDE HARM TO HEALTH

hselogo1HSE confirm lowest number of construction fatalities on record

Read the rest of this article »

Posted on 2nd November 2017

HSE ENFORCEMENT WEEKLY UPDATE OCT 25th 2017

hselogo1Prosecutions and enforcement notices weekly update and analysis

Read the rest of this article »

Posted on 25th October 2017

GIRDERS FELL DURING UNSAFE USE OF DEMO PLANT

Workman crushed and trapped by steel moved by company MD

Read the rest of this article »

Posted on 25th October 2017

FRAGILE ROOFLIGHT HAZARD LEFT UNCONTROLLED

Principal Contractor failed ensure covers or effective scaffolding installed

Read the rest of this article »

Posted on 25th October 2017

WORKING PLATFORM FELL FROM TELEHANDLER

Manufacturer instructions for safe platform attachment not followed

Read the rest of this article »

Posted on 25th October 2017

MAJOR CONTRACTOR FINED £640K OVER CO RISK

Simple marking required to control carbon monoxide gas

Read the rest of this article »

Posted on 23rd October 2017

PRISON TERM FOR SOLE TRADER CONTRACTOR

Small contractor pays the price for failing to manage work at height hazards

Read the rest of this article »

Posted on 19th October 2017

WORKMAN FELL THROUGH ROOF OPENING

Waterproof membrane concealed conservatory roof hazard

Read the rest of this article »

Posted on 19th October 2017

HSE ENFORCEMENT WEEKLY UPDATE 18th OCT 2017

hselogo1Prosecutions and enforcement notices weekly update and analysis

Read the rest of this article »

Posted on 19th October 2017
Turner Access Chipmunk Data
Total Access Ethentic
Higher Safety Turner Access