• Higher Safety Higher Safety Chipmunk Data Chipmunk Data

    M25 MEWP FATALITY: MANUFACTURER SAFETY NOTICE

    Genie safety notice issued on model involved in recent incident

    It has been reported by Vertikal that Genie has issued Safety Notice 130005 regarding the secondary boom angle sensor affecting all Genie Z135/70 machines. The notice follows a recent fatal incident at premises near the M25 motorway in London.

    Vertikal state that:

    “The requirement follows its own internal review of the machine and all of its primary and secondary (redundant) control systems, following the fatal overturning incident almost two months ago.

    The company says that it has found that some machines that were calibrated in the field may not have been calibrated according to the company’s service manual and therefore recommends that the secondary boom angle range is checked on all machines as a precaution.

    The company also states that this in no way indicates that this is what occurred with the recently delivered Kimberly Access machine that was involved in the incident.”

    The full statement by Terex is reported as follows:

    “Terex Aerial Work Platforms (AWP) continues to investigate the June 5, 2013 accident that occurred at the Kimberly Access site in London. As our thorough investigation has progressed, the integrity of the Genie Z-135/70 machines in the field continues to be confirmed. Genie Z-135/70 machines are safe to use as intended provided the machine is in proper working order, the operators are properly trained, and the owners/operators follow the warnings and instructions provided by Terex AWP, which are located on the machine.

    Terex AWP conducted an extensive review of the Genie Z-135/70 machines and has verified the Genie Z-135/70 production testing and audit procedures. Terex AWP also conducted an extensive review of all primary and secondary (redundant) control systems. These reviews have confirmed the effectiveness of the design and integrity of the Genie Z-135/70 machines. We continue to pursue information specific to the Kimberly Access incident and are fully cooperating with the HSE investigation.

    As part of Terex AWP’s review of the Genie Z-135/70, it has been made aware that in some instances, machines that were calibrated in the field were not calibrated in accordance with the machine’s service manual.

    Accordingly, we issued a Safety Notice affecting all Genie Z-135/70 machines. This safety notice is being issued to ensure that machines that were calibrated after leaving Terex AWP’s factory were calibrated in accordance with the procedures in the Genie Z-135/70 service manual.

    This Safety Notice requires a simple inspection of the secondary boom angle. Completing this inspection procedure will confirm whether the secondary boom angle sensor is properly calibrated and the machine is safe to use. To date, Terex AWP has not made any determination that the cause of the accident at Kimberly Access was due to improper calibration as described in the Safety Notice.”

    Latest Construction Health and Safety News

    CONSTRUCTION SAFETY NEWS – END OF NEW CONTENT

    The addition of content on this website ceased on 17th April 2020.

    Material posted before this date can be found by clicking on our SEARCH NEWS DATABASE function.

    Posted on 3rd May 2020

    HSE WARN OF NEED FOR RPE FACE FIT TEST AND CHECK

    Incorrectly fitted RPE will not protect the wearer from dangers to health

    Read the rest of this article »

    Posted on 16th April 2020

    CORONA VIRUS: LATEST SITE OPERATING PROCEDURES

    Industry Bodies publish risk management guidance Version 3

    Read the rest of this article »

    Posted on 15th April 2020

    TOWER CRANE OUT OF SERVICE SAFETY ALERT

    Important advice from Construction Plant-hire Association and HSE

    Read the rest of this article »

    Posted on 30th March 2020

    FRAGILE ROOF REPLACEMENT PUT WORKERS IN DANGER

    Measures to prevent falling from or through the roof were missing

    Read the rest of this article »

    Posted on 30th March 2020

    WORKMAN FELL FROM EDGE OF MEZZANINE FLOOR

    Edge protection was absent and workman untrained for the task

    Read the rest of this article »

    Posted on 30th March 2020

    HSE PLAN AND CONSTRUCTION PRIORITIES 2020/21

    Appointed CDM 2015 Principal Designers remain focus of HSE inspections

    Read the rest of this article »

    Posted on 30th March 2020

    COVID-19 ADVICE & GUIDANCE FOR CONSTRUCTION

    BuildUK support industry with advice, guidance and information

    Read the rest of this article »

    Posted on 30th March 2020

    LATEST HSE CONVICTIONS AND NOTICES REGISTERS

    hselogo1View current online HSE registers of prosecution convictions and notices

    Read the rest of this article »

    Posted on 30th March 2020

    POORLY DESIGNED SCHOOL GATE CRUSHED CHILD

    Sliding gate over-run mechanism proved insufficiently robust

    Read the rest of this article »

    Posted on 9th March 2020

    POWER GENERATOR PROSECUTED OVER UNSAFE SYSTEM

    Maintenance workers seriously injured when energy suddenly released

    Read the rest of this article »

    Posted on 2nd March 2020

    CEILING BELOW SAVES WORKMAN IN ROOFLIGHT FALL

    Roofworker fell through roof after stepping on fragile rooflight

    Read the rest of this article »

    Posted on 2nd March 2020

    INEXPERIENCED WORKER FELL THROUGH OPENING

    No physical protection or warning of opening and fragile covering

    Read the rest of this article »

    Posted on 29th February 2020

    CDM PRINCIPAL DESIGNER IN COURT OVER FIRE RISK

    Designers and contractor prosecuted for risk management failings

    Read the rest of this article »

    Posted on 29th February 2020

    PRISON SENTENCE FOR RECALCITRANT DIRECTOR

    Prohibition and improvement notices ignored and danger persisted

    Read the rest of this article »

    Posted on 26th February 2020

    TEMPORARY WORKS HOARDING FELL ON PEDESTRIAN

    Member of the public struck when site fence collapsed suddenly

    Read the rest of this article »

    Posted on 26th February 2020

    CHILD FATALLY INJURED BY UNSECURED POLE

    Pole stored on embankment moved and trapped boy against fencing

    Read the rest of this article »

    Posted on 26th February 2020

    OWNER RESPONSE TO HSE INSPECTION ENDED IN COURT

    Police uphold HSE right to inspect without threats, aggression or abuse

    Read the rest of this article »

    Posted on 24th February 2020

    HSE TARGETING WELDING FUME CANCER RISK

    Inspections to enforce improved controls required by new risk evidence

    Read the rest of this article »

    Posted on 24th February 2020

    CONTRACTOR FAILED TO REPLACE MISSING PROTECTION

    Painter and decorator fractured hip in fall from landing

    Read the rest of this article »

    Posted on 18th February 2020

    RISK OF DERMATITIS SUFFICIENT FOR PROSECUTION

    Company failed to implement controls and surveillance required by COSHH

    Read the rest of this article »

    Posted on 18th February 2020

    COSHH FAILINGS CAUSE ASTHMA AND PROVE COSTLY

    Uncontrolled exposure to isocyanates during paint spraying operations

    Read the rest of this article »

    Posted on 18th February 2020

    POLICE EMPLOYEE SHOCKED BY DATA CABLE WORK

    South Wales Force fined over electric shock from ceiling void cable

    Read the rest of this article »

    Posted on 18th February 2020

    COLLAPSE OF PUMP SET TRAPPED WORKMAN

    Unsafe system of work transferring from pallet to a raised platform

    Read the rest of this article »

    Posted on 18th February 2020

    MODIFIED PODIUM STEPS CAUSE FALL FROM HEIGHT

    Firm failed to select and correctly assemble with necessary training

    Read the rest of this article »

    Posted on 14th February 2020
  • Higher Safety Higher Safety Chipmunk Data Chipmunk Data