• Higher Safety Higher Safety Chipmunk Data Chipmunk Data

    M25 MEWP FATALITY: MANUFACTURER SAFETY NOTICE

    Genie safety notice issued on model involved in recent incident

    It has been reported by Vertikal that Genie has issued Safety Notice 130005 regarding the secondary boom angle sensor affecting all Genie Z135/70 machines. The notice follows a recent fatal incident at premises near the M25 motorway in London.

    Vertikal state that:

    “The requirement follows its own internal review of the machine and all of its primary and secondary (redundant) control systems, following the fatal overturning incident almost two months ago.

    The company says that it has found that some machines that were calibrated in the field may not have been calibrated according to the company’s service manual and therefore recommends that the secondary boom angle range is checked on all machines as a precaution.

    The company also states that this in no way indicates that this is what occurred with the recently delivered Kimberly Access machine that was involved in the incident.”

    The full statement by Terex is reported as follows:

    “Terex Aerial Work Platforms (AWP) continues to investigate the June 5, 2013 accident that occurred at the Kimberly Access site in London. As our thorough investigation has progressed, the integrity of the Genie Z-135/70 machines in the field continues to be confirmed. Genie Z-135/70 machines are safe to use as intended provided the machine is in proper working order, the operators are properly trained, and the owners/operators follow the warnings and instructions provided by Terex AWP, which are located on the machine.

    Terex AWP conducted an extensive review of the Genie Z-135/70 machines and has verified the Genie Z-135/70 production testing and audit procedures. Terex AWP also conducted an extensive review of all primary and secondary (redundant) control systems. These reviews have confirmed the effectiveness of the design and integrity of the Genie Z-135/70 machines. We continue to pursue information specific to the Kimberly Access incident and are fully cooperating with the HSE investigation.

    As part of Terex AWP’s review of the Genie Z-135/70, it has been made aware that in some instances, machines that were calibrated in the field were not calibrated in accordance with the machine’s service manual.

    Accordingly, we issued a Safety Notice affecting all Genie Z-135/70 machines. This safety notice is being issued to ensure that machines that were calibrated after leaving Terex AWP’s factory were calibrated in accordance with the procedures in the Genie Z-135/70 service manual.

    This Safety Notice requires a simple inspection of the secondary boom angle. Completing this inspection procedure will confirm whether the secondary boom angle sensor is properly calibrated and the machine is safe to use. To date, Terex AWP has not made any determination that the cause of the accident at Kimberly Access was due to improper calibration as described in the Safety Notice.”

    Latest Construction Health and Safety News

    HSE TO OVERSEE NEW BUILDING SAFETY REGIME

    Government to deliver biggest change in building safety for a generation

    Read the rest of this article »

    Posted on 21st January 2020

    CONTRACTS MANAGER HANDED TWO YEAR PRISON TERM

    Safety fall arrest netting would have saved life of deceased workman

    Read the rest of this article »

    Posted on 15th January 2020

    WORKER FATALLY INJURED BY CONCRETE BEAM

    Lifting operation not properly planned, managed and supervised

    Read the rest of this article »

    Posted on 15th January 2020

    TREE FELLING OPERATIONS LACKED DEFINED COMMS

    Workman struck by falling tree inside “normal” exclusion zone

    Read the rest of this article »

    Posted on 14th January 2020

    CONTRACTOR ARRESTED OVER WELFARE FAILINGS

    Recalcitrant sole trader failed to attend court hearing

    Read the rest of this article »

    Posted on 14th January 2020

    MAJOR DEMOLITION CONTRACTOR FINED £500,000

    Collapse of concrete slab caused death of worker and excavator fall

    Read the rest of this article »

    Posted on 14th January 2020

    FALL FROM LADDER WHILST CARRYING BUCKET

    Contractor failed to provide basic safe lifting aids

    Read the rest of this article »

    Posted on 14th January 2020

    FAILURE TO COMPLY WITH HSE NOTICE PROVES COSTLY

    Director given suspended jail term and company fined £60,000

    Read the rest of this article »

    Posted on 14th January 2020

    DEVELOPER FAILED TO PLAN AND CHECK COMPETENCE

    Fall caused by ad-hoc working methods and lack of monitoring

    Read the rest of this article »

    Posted on 14th January 2020

    CYLINDER LEAK TEST CAUSED FATAL INJURIES

    Corrosion inhibitor triggered failure and shrapnel ejection

    Read the rest of this article »

    Posted on 14th January 2020

    FESTIVE GREETINGS TO ALL OUR READERS

    Read the rest of this article »

    Posted on 20th December 2019

    JAIL TERM FOLLOWS ROUTINE HSE SPOT CHECK

    Director of a roofing firm handed a suspended prison sentence

    Read the rest of this article »

    Posted on 19th December 2019

    TEENAGER FELL 3M DURING BLOCK AND BEAM WORK

    Workers uninstructed and left to devise own safe system of work

    Read the rest of this article »

    Posted on 19th December 2019

    PARCEL CARRIER FINED HEAVILY OVER FLT INCIDENT

    Reversing fork lift lacked segregation from pedestrians

    Read the rest of this article »

    Posted on 18th December 2019

    CONTRACTOR FINED OVER FLOOR OPENING FALL

    Thorough risk assessment and edge protection were both inadequate

    Read the rest of this article »

    Posted on 18th December 2019

    THREE WORKERS “CARRIED ALONG” IN SEWER INCIDENT

    Mentally affected and one man treated for long-term traumatic stress

    Read the rest of this article »

    Posted on 11th December 2019

    SOLAR FIRM AND DIRECTOR SENTENCED OVER DEATH

    Brother of business owner died in fall during panel installation

    Read the rest of this article »

    Posted on 10th December 2019

    DIRECTOR AND COMPANY FINED FOR ASBESTOS RISK

    HSE refurbishment campaign inspection revealed asbestos offences

    Read the rest of this article »

    Posted on 10th December 2019

    BULK BAG COLLAPSE CAUSED BY UNSAFE STACKING

    Bulk bag collapsed onto workman when struck by fork lift

    Read the rest of this article »

    Posted on 9th December 2019

    INTERLOCKED GUARD NOT WORKING TO ISOLATE POWER

    Two workmen seriously injured when plant started unexpectedly

    Read the rest of this article »

    Posted on 9th December 2019

    STREET FURNITURE RISK TO PUBLIC FINED £1.4M

    Council prosecuted following injury to child playing on hinged bollard

    Read the rest of this article »

    Posted on 9th December 2019

    WORKMEN SUFFER SERIOUS BURNS FROM CABLE STRIKE

    Assessment and system of work failed to appreciate electrical risk

    Read the rest of this article »

    Posted on 29th November 2019

    LADDERS WERE INAPPROPRIATE FOR WORK ON ROOF

    Workman paralysed after falling whilst installing roof ladder

    Read the rest of this article »

    Posted on 28th November 2019

    FIRM FAILED TO MANAGE EXHAUST VENTILATION

    HSE enforcement notices on wood dust and welding fume ignored

    Read the rest of this article »

    Posted on 27th November 2019

    RECALCITRANT DIRECTOR BARRED FROM OFFICE

    Dangerous telehandler used despite earlier fatality and enforcement

    Read the rest of this article »

    Posted on 25th November 2019
  • Higher Safety Higher Safety Chipmunk Data Chipmunk Data