    IMPROVING SITE SAFETY WHILST CUTTING PROJECT COSTS

    Effective coordination early in project design secures safety of all at lower cost

    Construction Index has published a Case Study from Combisafe International demonstrating how the cost of edge protection was reduced on a major construction project.

    This was achieved by connecting the steel fabricator and edge protection supplier at an early stage in the project design thereby enabling selection of an edge protection system which satisfied the needs of all trades throughout the project.

    The article is reproduced verbatim below.

    Cut the cost of edge protection

    On most construction projects, the Client pays at least three times for edge protection. The frame package normally includes the requirement to provide the edge protection first.

    This is installed at minimum cost and inconvenience to the installing trade, as they gain no benefit from it. Invariably the edge protection then hinders the first protected trade and gets moved. There is often a delay period between slab completion and cladding arriving, and responsibility for the edge protected area changes. At this point the equipment being used is reviewed and frequently changed or adjusted. Finally the cladding activity arrives and the edge protection is in the way again, frustrating access to the building edge. This regularly results in another change or move. All this costs money, and it is primarily due to a lack of detailed planning, limited flexibility within the edge protection provided, and invariably poor communication between the trades.

    For Ormiston Academy, a six-storey specialist BSF Academy for media studies being built in steel within a regeneration area in Birmingham, Bovis Lend Lease decided to challenge this general situation. By connecting Elland Steel Structures, the steel fabricator, and Combisafe, Europe’s leading edge protection supplier, at an early stage in the project design, a significantly flexible edge protection system was selected, that satisfied the needs of all the protected trades at every stage of the project. This early decision also allowed the steel design to accommodate the fixing needs of the edge protection selected.

    The project demanded an edge protection system to meet the European Standard, EN 13374 Class A. It needed to be up to 2m high to contain windblown debris and materials, and required a mesh panel and toe board. It also needed to allow access to the building edge for installation of the cladding system fixing cleats, preferably whilst protecting the cladding installers.

    The site team decided to use a 2m high system based upon the Combisafe SMB (Steel Mesh Barrier). This satisfied both the compliance and the containment issues. The system could be pre-installed into sockets or bolt holes pre-positioned by Elland within the perimeter steel work, thus minimising work at height during installation. By additionally specifying the Combisafe SMB Beam Holders to be used in all locations, the whole edge protection system attracted substantial additional flexibility.

    These SMB Beam Holders allow a double guard rail beam to be positioned outside the line of the SMB and to be supported on the same posts. The SMB Beams are put in place over the existing system, whilst at all times the installer is protected from falling by the previously installed SMB. The beams can be used in isolated locations, on various levels, or along whole elevations. Once the SBM Beam is in place, the SMB panel can be removed from the inside, allowing protected free access to the edge of the building, and allowing the cladding contractor to reach through the SMB Beam to position and fix the cladding cleats.

    The project was a total success, with high productivity in both the frame erection and the cladding installation. The foresight shown by Bovis Lend Lease, in connecting Elland Steel Structures and Combisafe’s engineering service at so early a stage in the project, ensured that in this unique situation the Client only paid once.

    In this way the edge protection was initially installed to the perimeter steel work at ground level, and subsequently could be adjusted in position and worked through, in any location on the project. At all times the installers and other trades were collectively prevented from falling, and at no time needed to use a harness and lanyard.

    Latest Construction Health and Safety News

    HSE ENFORCEMENT DATABASE LATEST UPDATE

    hselogo1View current online register of HSE prosecutions and enforcement notices

    Read the rest of this article »

    Posted on 14th August 2019

    FALL PRECAUTIONS FELL BETWEEN TWO FIRMS

    Contractors fined after workers at risk of falling from roof

    Read the rest of this article »

    Posted on 9th August 2019

    SOLAR PANEL FIRM AWARE OF FRAGILE ROOF RISK

    Workman suffered long-term injuries in 4m fall through rooflight

    Read the rest of this article »

    Posted on 9th August 2019

    HSE PROSECUTE FIRM OVER RISK NOT HARM

    Multiple safety failings land construction company in court

    Read the rest of this article »

    Posted on 9th August 2019

    CLIENT AND CONTRACTOR FACED COURT TOGETHER

    Firms breached joint duty to plan and carry our work at height safely

    Read the rest of this article »

    Posted on 6th August 2019

    £1M FINE OVER DEATH CAUSED BY EXCAVATOR

    Vehicle driver found guilty at trial alongside CDM Principal Contractor

    Read the rest of this article »

    Posted on 6th August 2019

    CHILD DIED WHILST PLAYING ON POWERED GATE

    Lack of end stop caused gate to fall on 6 year old boy

    Read the rest of this article »

    Posted on 6th August 2019

    HSE SPEAK AT ACCESS INDUSTRY CONFERENCE 2019

    AIF National Working at Height Conference November 2019

    Read the rest of this article »

    Posted on 6th August 2019

    UK CLIENT FINED OVER UNSAFE OVERSEAS FIRM

    Italian contractor found guilty despite failure to attend court

    Read the rest of this article »

    Posted on 6th August 2019

    COMPLETE FAILURE TO RECOGNISE HAVS RISK

    Specialist drilling company and director sentenced over HAVS danger

    Read the rest of this article »

    Posted on 6th August 2019

    PC AND TWO OTHERS FAILED TO ASSESS WIND EFFECT

    Fall of director from roof caused by ‘Storm Doris’ gust

    Read the rest of this article »

    Posted on 30th July 2019

    MAJOR FIRM FINED £400k OVER LIFTING OPERATION

    Fitter loses four fingers as load slides and falls to the ground

    Read the rest of this article »

    Posted on 28th July 2019

    NEW HOMES LEFT IN DANGEROUS CONDITION

    Fined for unsafe gas work causing fires at housing development

    Read the rest of this article »

    Posted on 28th July 2019

    FIRM FINED £1M OVER EXPLOSION DURING CLEANING

    Tank cleaning operation caused burns as flammable vapours ignited

    Read the rest of this article »

    Posted on 25th July 2019

    YOUNG BRICKLAYER FELL THROUGH OPEN STAIRWAY

    Firm fined over failure to install fall protection around opening

    Read the rest of this article »

    Posted on 25th July 2019

    STRUCTURAL SAFETY BODY LATEST NEWSLETTER

    CROSS publishes reports and expert comment on a range of issues

    Read the rest of this article »

    Posted on 23rd July 2019

    FLAT ROOF FAILED UNDER WEIGHT OF WORKMAN

    Confusion over fragility proves costly for worker and business

    Read the rest of this article »

    Posted on 23rd July 2019

    PROPERTY FIRM FINED OVER FATAL FALL FROM TREE

    Untrained workers using chain saw engaged to fell large sycamore

    Read the rest of this article »

    Posted on 23rd July 2019

    LANDLORD PUT PUBLIC AT RISK FROM ASBESTOS

    Powered jet washing of asbestos cement sheets caused spread

    Read the rest of this article »

    Posted on 23rd July 2019

    WORKMAN FELL FROM SUSPENDED ACCESS EQUIPMENT

    Health Board and maintenance firm director prosecuted

    Read the rest of this article »

    Posted on 23rd July 2019

    CONSIDERING TEMP WORKS IN PERMANENT DESIGN

    Useful overview for civil and structural engineers on contemporary practice

    Read the rest of this article »

    Posted on 23rd July 2019

    FIRM FAILED TO COMPLY WITH SITE WELFARE NOTICE

    Basic welfare requirements found wanting for second time

    Read the rest of this article »

    Posted on 23rd July 2019

    PRISON TERM OVER POORLY GUARDED CIRCULAR SAW

    Workman lost three fingers using machine without guard and riving knife

    Read the rest of this article »

    Posted on 23rd July 2019

    COMPANY IGNORED HSE ON SILICA DUST ACTION

    Worktop manufacturer failed to control dust and manage ventilation

    Read the rest of this article »

    Posted on 23rd July 2019

    ASBESTOS REMOVED WITHOUT SURVEY OR CONTROLS

    Client fined over failure to commission refurb and demo survey

    Read the rest of this article »

    Posted on 15th July 2019
    Ethentic Ethentic Higher Safety Higher Safety Chipmunk Data Chipmunk Data
  • Higher Safety Higher Safety Chipmunk Data Chipmunk Data Ethentic Ethentic