    HSE SAFETY NOTICE: CRUSH RISK ON POWERED GATES

    Death of two children prompts HSE gate safety standard update notice 

    HSE has issued HSE Safety Notice FOD 7-2010 aimed at organisations and individuals involved in the design, construction, installation and commissioning of electrically powered gates and organisations in control of their use and/or maintenance. It is also relevant to companies carrying out on-going maintenance of these types of gates.

    Recent separate incidents involving the death of two young children have highlighted a risk of using automatic vehicle access gates. 

    The children were trapped between the closing edge of the gate and the gate post at the end of the gates’ travel. Trapping occurred because:

    • presence in the vicinity of the closing edge was not detected; and
    • closing force of the gate when they obstructed it was not limited to the values specified in Annex A of BS EN 12453:2001.
    Installers must take action

    The police and HSE investigations continue into both deaths.

    HSE says it wants to make it clear to installers “must take action to prevent pedestrians from becoming trapped in electric gates”.  THe HSE Director of Field Operations, David Ashton, said:

    “Electric or automatic gates are designed to stop if someone gets in the way, and installers and those maintaining these gates have a real duty to ensure this happens.

    They must take their responsibilities seriously to make sure that anti-crushing, shearing and trapping safety protection devices are correctly set and maintained.”

    When manufacturing, designing or installing electric gates, it’s crucial to consider who will be in the area when it’s operating. If general public can access the gate then additional protections should be in place.

    These protections can be in the form of creating safe distances, installing fixed guards, limiting the forces or installing sensitive protective equipment – among others.”

    Action required

    The HSE Safety Notices states that the following action is required:

    1. “All designers and installers of electrically powered gates should ensure that the forces generated by a gate when meeting a person or an obstacle are limited and that they do not exceed the values specified in Annex A of BS EN 12453:2001.
    2. These forces should be measured in accordance with BS EN 12445:2001. “Industrial commercial and garage doors and gates. Safety in use of power operated doors. Test methods” and the performance of the system validated before the gate is put into use.
    3. Forces should be periodically re-measured and checked as part of the planned preventative maintenance schedule for the gates.
    4. In addition to force limitation, additional safeguards, such as pressure sensitive strips on the closing edge and photoelectric sensing devices, should be fitted where the risk assessment identifies the gate as high risk, in that it is operating automatically in a public place where children and other members of the public may be present.
    5. Persons or organisations in control of powered gates should periodically review their risk assessments to ensure that they identify any changes to the environment or operating conditions and that they have taken appropriate steps to address them. This is particularly important when the responsibility for management of the gate passes from one person or organisation to another.
    6. Other hazards associated with the opening and closing of the gate should also be addressed – these will include crushing, shearing, impact and drawing-in hazards. Examples of other hazard points are described in BS EN 12453: 2001 and include: the opening edge; gaps in the gate where they pass fixed structures; and at the drive mechanism. (Note: force limitation on its own is also unlikely to be sufficient for these hazards).
    7. All safety devices and features should be checked on a regular basis and in accordance with the manufacturer’s instructions to ensure they continue to function as designed to ensure that safety is maintained. This should be specified in a planned preventative maintenance schedule agreed by persons responsible for the gate’s management and their appointed maintenance company.”

    Latest Construction Health and Safety News

    SELECTED NEWS POSTED RECENTLY ON TWITTER

    PP Construction Safety logo and link to home page [1]Links to other construction health and safety related news reports

    Read the rest of this article »

    Posted on 18th November 2019

    HSE LOOK TO LOCAL AUTHORITIES FOR CDM SUPPORT

    Council Inspectors focus on CDM client duties – asbestos, fragility and RCS

    Read the rest of this article »

    Posted on 14th November 2019

    VERBAL WARNING OF DANGER IS NO DEFENCE

    Hand of female worker entangled in modified metal drilling rig

    Read the rest of this article »

    Posted on 14th November 2019

    UNDERGROUND CABLE STRIKE CAUSES 50% BURNS

    Workman seriously injured using hand-held breaker to excavate post holes

    Read the rest of this article »

    Posted on 14th November 2019

    HSE WELDING FUME REVISED GUIDANCE PUBLISHED

    New research evidence on cancer link prompts revision on welding fume

    Read the rest of this article »

    Posted on 14th November 2019

    VIBRATION MANAGEMENT FAILINGS FINED £600,000

    Vital health surveillance, tool replacement and management found wanting

    Read the rest of this article »

    Posted on 14th November 2019

    HSE ENFORCEMENT DATABASE LATEST UPDATE

    hselogo1View current online register of HSE prosecutions and enforcement notices

    Read the rest of this article »

    Posted on 31st October 2019

    DEVELOPER AND DIRECTOR PUT PUBLIC AT RISK

    Demolition undertaken without surveys and effective safety precautions

    Read the rest of this article »

    Posted on 28th October 2019

    BY-PASSING MACHINE INTERLOCK FINED £1.275 MILLION

    Trapped key safety system failed to prevent access to conveyor danger

    Read the rest of this article »

    Posted on 24th October 2019

    HSE LOSES PATIENCE WITH ERRANT CONTRACTOR

    Roofing firm fined £30,000 over failure to manage work at height risks

    Read the rest of this article »

    Posted on 24th October 2019

    TRUSS ERECTION LACKED INTERNAL FALL PROTECTION

    Carpenter fell and injured whilst falling with roof truss

    Read the rest of this article »

    Posted on 24th October 2019

    WORKMAN FELL HEAD FIRST THROUGH ROOFLIGHT

    Fragile roof dangers not assessed and properly controlled

    Read the rest of this article »

    Posted on 24th October 2019

    STRUCTURAL SAFETY BODY LATEST NEWSLETTER

    CROSS publishes reports and expert comment on a range of issues

    Read the rest of this article »

    Posted on 18th October 2019

    HSE RISK REDUCTION THROUGH DESIGN AWARD

    Regulator seeks to promote hazard avoidance and risk minimisation

    Read the rest of this article »

    Posted on 18th October 2019

    CLIENT AND CONTRACTOR FINED OVER ASBESTOS RISK

    Checks for presence of asbestos not undertaken prior to refurbishment

    Read the rest of this article »

    Posted on 18th October 2019

    DIRECTOR PROSECUTED AND JAILED AS EMPLOYEE

    Workman fatally injured when crushed between bucket and wall

    Read the rest of this article »

    Posted on 18th October 2019

    BUILDING MATERIALS FIRM FINED OVER FATALITY

    Failure to effectively isolated power to machinery caused death of engineer

    Read the rest of this article »

    Posted on 10th October 2019

    CUSTOM AND PRACTICE CAUSED EXPLOSION DEATHS

    Electrical accumulator explosion claims the lives of two engineers

    Read the rest of this article »

    Posted on 10th October 2019

    REBAR FELL DURING TANDEM FLT LIFTING OP

    Workman seriously injured during improperly planned and executed lift

    Read the rest of this article »

    Posted on 10th October 2019

    FIRM FINED AFTER FINGER OF TRAINEE SEVERED

    Young worker injured hand working on unguarded rip saw

    Read the rest of this article »

    Posted on 8th October 2019

    WORKMAN FELL THROUGH ROOF OPENING

    Contractor failed to provide collective edge protection or fall arrest

    Read the rest of this article »

    Posted on 7th October 2019

    DRIVER UNDER TRAINING CRUSHED BY TELEHANDLER

    Court sentences company director to unpaid work community order

    Read the rest of this article »

    Posted on 30th September 2019

    DIRECTOR IN DOCK OVER FRAGILE ROOF RISK

    Roofing contractor and director failed to plan and manage falls risk

    Read the rest of this article »

    Posted on 30th September 2019

    HSE START PROJECT HEALTH RISK INTERVENTIONS

    Regulator set to check health risks assessed and controls in place

    Read the rest of this article »

    Posted on 30th September 2019

    AIF NATIONAL WORKING AT HEIGHT CONFERENCE

    HSE Construction Head to speak at Access Industry Forum conference

    Read the rest of this article »

    Posted on 23rd September 2019
  • Higher Safety Higher Safety Chipmunk Data Chipmunk Data